Diagnosis de averías, con mando a distancia
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SPLIT
• Check pressure, the maximum reference must be 2 bar in low pressure and 12 bar in
high pressure at an outside temperature of 35ºC.
• Keep the recirculation input in the base of the device free.
• Clean the capacitor / grille.
• Replace the electro(s).
• Check that the air is discharged to the outside; if it is not, invert the connector connection.
• Check the current output in electronic control, replacing whenever there is no + and - output.
• Replace the blower or connect the terminals.
• Replace the electronic control or control board.
• Connect the belt properly.
• Correctly connect the control module terminals (in accordance with the attached wiring
diagram).
• Replace the module.
• Replace the compressor.
• Charge or replace the battery.
• Change the pressure switch or check the terminals.
• Replace the relays or check the terminals.
• Replace the cable or check the terminals.
Solution
13