11. Assembly of hygiene box
Warning!
• Operate the product only with safety extra low voltage (SELV). The components
must not be earthed.
• Protect the mains-side power supply with a residual current circuit breaker (RCD).
Failure to observe this instruction can result in death or material damage due to
electric shock or fire, for example.
☞
To protect the tiles, use masking tape when marking and drilling. Drill at low speed.
☞
Depending on the composition of the wall, special wall plugs may have to be used
(to be provided by the customer).
Fig. A: Hygiene box right of drain
Fig. B: Hygiene box left of drain
11.1 Install the hygiene box (a) from
Only for hygiene box left of drain:
11.2 Use a screwdriver to lever the top cap (b) up and the bottom cap (c) down.
11.3 Remove the front cover (d).
11.4 Turn the lower part of the housing (e) by 180°.
☞
The sensor is located in the upper part of the front cover.
11.5 Press the front cover (d) onto the lower part of the housing (e) and snap the cap (c)
into the front cover (d).
11.6 Lever the cap (b) up with a screwdriver.
11.7 Fold the front cover (d) down.
11.8 Mark the drill holes for attaching the lower part of the housing.
☞
To protect the tiles, use masking tape when marking and drilling. Drill at low speed.
☞
Depending on the composition of the wall, special wall plugs may have to be used
(to be provided by the customer).
11.9 Drill holes in accordance with these markings.
11.10 Insert the wall plugs.
11.11 Fasten the lower part of the housing.
☞
Important!
The solenoid valve cartridges must be connected before the power supply is
connected.
11.12 Connect the black plug to the solenoid valve cartridge for cold water.
Work step
11.6.
- 7 -