Replacing The Solenoid Valve Cartridge; Spare Parts - Franke ACLM1001 Instrucciones De Montaje Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

18. Replacing the solenoid valve cartridge

18.1 Close the angle valves.
18.2 Trigger the tap.
18.3 Remove the battery compartment or wall installation power pack from the sensor.
18.4 Remove the sensor (b) from the solenoid valve cartridge (a).
18.5 Loosen the solenoid valve cartridge (a), using an open-ended wrench.
Important!
The solenoid valve cartridge must be connected before the power supply is
connected.
18.6 Reassemble in reverse order.

19. Spare parts

Description
Solenoid valve cartridge. . . . . . . . . . . 2030045522
Sensor type 8. . . . . . . . . . . . . . . . . . . 2030041487
Accessories
Order No.
Remote control. . . . . . . . . . . . . . . . . . 2030036654
2-button remote control . . . . . . . . . . . 2030036849
Battery compartment . . . . . . . . . . . . . 2000109466
Plug-in power supply . . . . . . . . . . . . . 2030039823
- 12 -
Order No.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Aclm100320300412562030041258

Tabla de contenido