en | MIC-ALM-WAS-24 Layout
12
2014.09 | 1.3 | F.01U.305.934
1 Hole for lid screw [four (4) total]
2 Hole for mounting screw [four (4) total]
3 Cable gland, size M16, intended for 24 VAC power cable
4 Terminal block (3-pin, labeled P300 / Voltage In) for 24 VAC power cable
5 [Not used]
6 Terminal block (12-pin, labeled P101) for alarm connections
7 Alarm LEDs (labeled AO1, AO2, AO3, AI1, AI2, AI3, AI4)
8 Terminal block (3-pin, labeled P200) for RS-485 connections
9 Cable gland, size M16, intended for RS-485 connections from camera
10 Terminal block (2-pin, labeled P100) for connections to washer
11 Push button (red; labeled PUMP ON) to activate/test the washer
12 Cable gland, size M16, intended for connections to washer
13 LED (labeled Washer LED) to indicate activity of washer
14 Cable gland, size M16, intended for alarm input/output connections [Supplied but not
factory-installed]
15 LED to indicate power (Red indicates power on)
16 LED (labeled ACTIVITY) to indicate communications between the MIC-ALM-WAS-24
and the camera