Bosch MIC-ALM-WAS-24 Manual De Instalación página 14

Ocultar thumbs Ver también para MIC-ALM-WAS-24:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 60
en | Installation
14
Figure 6.1: Dimensions, mounting holes, MIC-ALM-WAS-24
4. Refer to installation information on the lid label.
5. Connect the RS-485 communication cable from the camera to the device.
Pin
1
2
3
6. Connect the power cable.
2014.09 | 1.3 | F.01U.305.934
Refer to the label on the inside of the lid of the enclosure for important installation
information.
Prepare the cable as needed.
Select the cable gland in the most suitable location based on installation conditions. Item
9 is recommended.
Feed the cable through the cable gland into the enclosure.
Make the connections to terminal block P200 (item 8) according to the table below.
Description / Function
Data-
Ground
Data+
Check that the connections are secure.
Prepare the cable as needed.
Select the cable gland in the most suitable location based on installation conditions. Item
3 is recommended.
Feed the cable through the cable gland into the enclosure.
Make the connections to terminal block P300 (item 4) according to the table below.
188 mm