en | Product overview
8
3

Product overview

The MIC Alarm/Washer Interface (MIC-ALM-WAS-24) provides the following features:
The 3-wire RS-485 cable from the base of the camera feeds through the watertight cable gland
in the enclosure and connects to terminal block P200 on the PCBA.
The device requires a 24 VAC, 50/60 Hz, 1A power source (user-supplied). All input/output
connections (for external connections) have surge protection against ESD, RFI and voltage
transients.
The enclosure, rated to IP67, is made of impact-resistant polycarbonate to withstand exposure
to wet environments.
2014.09 | 1.3 | F.01U.305.934
user connections for alarms inputs
user connections for alarm outputs
user connections for a washer (used to spray water or cleaner on the viewing window of
the camera) that is connected to the interface
a push button on the PCBA to allow users to activate/test the washer