RESP and stop management
• 000: In normal operating mode, it saves the position; in case of RESP, it searches for the opening reference.
• 001: In the normal operating mode, it saves the position; in case of RESP, it searches for the closing reference.
• 002: Searches for the stop only on opening, while on closing it stops on the memorised point. In case of RESP it
starts on opening.
• 003: Searches for the stop only on closing, while on opening it stops on the memorised point. In case of RESP it
starts on closing.
• 004: Searches for the stop on closing and on opening. In case of RESP it starts on opening.
• 005: Searches for the stop on closing and on opening. In case of RESP it starts on closing.
Note: The only direction allowed in case of RESP is the set direction, in case of reversals (PHOTO, SAFETY) it stops
the movement.
Note: It can be used to facilitate the passing of the impact tests on garage doors at the H-300mm point.
Mo.18
Double-Phase Acceleration
If activated, it executes an acceleration ramp until reaching the slow down
speed determined by parameter Mo.01 or Mo.06, until the end of the
acceleration space (Mo.03 or Mo.08), after which the speed goes to the
maximum speed.
Note: This parameter can be used to facilitate the impact tests during the
closing manouver at the point: H-300mm. (H = height of the sectional door)
Mo.19
Initial surge duration on opening
• 000: Initial surge deactivated (performs a very short, almost imperceptible surge)
• 00X: Adjusts the duration of the surge up to 2,5s (X*10 ms)
Mo.20
Initial surge duration on closing
• 000: Initial surge deactivated (performs a very short, almost imperceptible surge)
• 00X: Adjusts the duration of the surge up to 2,5s (X*10 ms)
Mo.21
Stop margin at opening
Space at the end of the opening manoeuvre performed with deceleration speed and without reversing onto an
obstacle. Expressed in thousandths of the total stroke.
(0...................................255)
Mo.22
Stop margin at closing
Space at the end of the closing manoeuvre performed with deceleration speed and without reversing over an
obstacle. Expressed in thousandths of the total stroke.
(0...................................255)
Mo.23
Not Used
Mo.24
Not Used
Mo.25
Not Used
Mo.26
Not Used
Mo.27
Not Used
Mo.28
Anti-tampering brake
Parameter intended for sectional doors. Allows to counteract any motor
movements that are detected when the automation is not in operation.
In this case the motor will be activated inthe opposite direction to the
movement detected, in order to keep the automation position unchanged.
Warning: It is necessary to have a double channel encoder wired and
enabled (SY.04=002).
Warning: If active (Mo.28 = 001,002,003) it is NECESSARY to set parameter
Mo.17 = 002 and install the mechanical stop (art. AB / FM not supplied) on
the track in the open position.
46
002
001
000
000
• 000: Disabled
• 001: Active only in opening
• 002: Active only in closing
• 003: Active both in opening and
closing
000
000
000
000
010
100
010
030
000
000
• 000: Disabled
• 001: Active only with the gate closed
• 002: Active only with the gate open
• 003: Active both with the gate
closed and open