7.14
GAS_COST
7.15
ELE_COST
7.16
MAX_SETHEATER
7.17
MIN_SETHEATER
7.18
MAX_SIGHEATER
7.19
MIN_SIGHEATER
7.20
TBH FUNCTION
7.21
dT5_TBH_OFF
7.22
t_TBH_DELAY
7.23
T4_TBH_ON
7.24
P_TBH
7.25
SOLAR FUNCTION
7.26
SOLAR CONTROL
7.27
DELTASOL
8.1
T1S_H.A_H
8.2
T5S_H.A_DHW
PREHEATING FOR
FLOOR-T1S
12.1
12.1
t_FIRSTFH
FLOOR DRYING UP
t_DRYUP
t_HIGHPEAK
t_DRYD
t_DRYPEAK
12.2
START TIME
START DATE
AUTO RESTART
13.1
COOL/HEAT MODE
AUTO RESTART DHW
13.2
MODE
POWER INPUT
14.1
LIMITATION
State
Price of gas
Price of electricity
Maximum setting temperature of additional heating source
Minimum setting temperature of additional heating source
The voltage corresponding to the maximum setting
temperature of additional heating source
The voltage corresponding to the minimum setting
temperature of additional heating source
Enable or disable the TBH(TANK BOOSTER HEATER)
function:0=NON,1=YES
The temperature difference between T5 and T5S(The set
water tank temperature) that turns the booster heater off.
The time that the compressor has run before starting the
booster heater
The ambient temperature for starting the tank booster
heater
Power input of TBH
Enable or disable the SOLAR function:0=NON,1=ONLY
SOLAR, 2=SOLAR+HP(HEAT PUMP)
The solar pump (pump_s) control method :0=Tsolar,
1=SL1SL2
The deviation temperature that SOLAR turns on
The target outlet water temperature for space heating
in holiday away mode
The target tank temperature for domestic hot
water heating in holiday away mode
The setting temperature of outlet water during first
preheating for floor
Running time for first preheating of the floor
The function of drying up the floor
Temp-up days for floor drying up
Days for floor drying up
Temp-down days for floor drying up
Outlet temperature of floor drying up
The start time of floor drying up
The start date of floor drying up
Enable or disable the auto restart cooling/heating
mode. 0=NON,1=YES
Enable or disable the auto restart DHW mode.
0=NON,1=YES
The type of power input limitation
50
Default
Unit
0.85
€/m
3
0.20
€/kWh
80
°C
30
°C
10
V
3
V
1
/
5
°C
30
min
5
°C
2
kW
0
/
0
/
10
°C
25
°C
25
°C
25
°C
72
HOUR
/
/
8
DAY
5
DAY
DAY
5
°C
45
Hour : the
present
time(not on
h/min
the hour +1,
on the hour
+2)
Minute:00
The present
d/m/y
date
1
/
1
/
0
/