11.1 Setting parameters
The parameters related to this chapter are shown in the table below.
Order
Code
number
1.1
DHW MODE
1.2
DISINFECT
1.3
DHW PRIORITY
1.4
PUMP_D
1.5
DHW PRIORITY TIME SET Enable or disable the DHW priority time set:0=NON,1=YES
1.6
dT5_ON
1.7
dT1S5
1.8
T4DHWMAX
1.9
T4DHWMIN
1.10
t_INTERVAL_DHW
1.11
T5S_DISINFECT
1.12
t_DI_HIGHTEMP
1.13
t_DI_MAX
1.14
t_DHWHP_RESTRICT
1.15
t_DHWHP_MAX
1.16
PUMP_D TIMER
1.17
PUMP_D RUNNING TIME The certain time that the DHW pump will keep running.
1.18
PUMP_D DISINFECT
1.19
ACS FUNCTION
2.1
COOL MODE
2.2
t_T4_FRESH_C
2.3
T4CMAX
2.4
T4CMIN
2.5
dT1SC
2.6
dTSC
2.7
t_INTERVAL_C
2.8
T1SetC1
2.9
T1SetC2
2.10
T4C1
2.11
T4C2
2.12
ZONE1 C-EMISSION
2.13
ZONE2 C-EMISSION
3.1
HEAT MODE
3.2
t_T4_FRESH_H
State
Enable or disable the DHW mode:0=NON,1=YES
Enable or disable the disinfect mode:0=NON,1=YES
Enable or disable the DHW priority mode:0=NON,1=YES
Enable or disable the DHW pump mode:0=NON,1=YES
The temperature difference for starting the heat pump
The difference value between Twout and T5 in DHW mode
The maximum ambient temperature that the heat pump
can operate at for domestic water heating
The minimum ambient temperature that the heat pump can
operate for domestic water heating
The start time interval of the compressor in DHW mode.
The target temperature of water in the domestic hot water
tank in the DISINFECT function.
The time that the highest temperature of water in the
domestic hot water tank in the DISINFECT function will last.
The maximum time that disinfection will last.
The operation time for the space heating/cooling operation.
The maximum running time of heat pump in DHW
PRIORITY mode.
Enable or disable the DHW pump run as timed and keeps
running for PUMP RUNNING TIME:0=NON,1=YES
Enable or disable the DHW pump operates when the unit
is in disinfect mode and T5≥T5S_DI-2:0=NON,1=YES
Enable or disable the second water tank control T5_2:
0=NON,1=YES
Enable or disable the cooling mode:0=NON,1=YES
The refresh time of climate related curves for cooling mode
The highest ambient operation temperature for cooling mode
The lowest ambient operating temperature for cooling mode
The temperature difference between T1 and T1S(the set
water temperature) for starting the heat pump
The temperature difference between actual room
temperature Ta and the set room temperature Tas for
starting the heat pump.
The start time interval of the compressor in cooling mode
The setting temperature 1 of climate related curves for
cooling mode.
The setting temperature 2 of climate related curves for
cooling mode.
The ambient temperature 1 of climate related curves for
cooling mode.
The ambient temperature 2 of climate related curves for
cooling mode.
The terminal type of zone 1 for cooling mode: 0=FCU(fan
coil unit), 1=RAD.(radiator), 2=FHL(floor heating loop)
The terminal type of zone 2 for cooling mode: 0=FCU(fan
coil unit), 1=RAD.(radiator), 2=FHL(floor heating loop)
Enable or disable the heating mode
The refresh time of climate related curves for heating mode
48
Default
Unit
/
1
/
1
1
/
0
/
0
/
10
°C
10
°C
43
°C
-10
°C
5
MIN
65
°C
15
°C
MIN
210
30
°C
MIN
90
/
1
5
MIN
/
1
/
0
1
/
0.5
hours
52
°C
10
°C
5
°C
2
°C
5
min
10
°C
°C
16
°C
35
25
°C
0
/
0
/
/
1
0.5
hours