INSTALLATION INSTRUCTIONS
High Flow Valve
Setscrew
CAUTION: Risk of personal injury. The water temperature should never be set above 120° F (49° C).
NOTE: Do not remove the O-ring and collar at this time. Removing the O-ring and collar will change the
factory setting for the maximum water temperature.
Discard the plaster guard.
Turn the valve clockwise to the full open position. After several minutes, check the temperature.
For minor temperature changes, adjust the setscrew and recheck the temperature.
For major temperature changes, remove the o-ring and the collar. Slowly turn the valve stem to adjust the
maximum water temperature.
Reinstall the collar with the setscrew against the tab. Reinstall the O-ring.
Recheck the temperature.
Turn the valve stem counterclockwise to the "OFF" position.
NOTE: After adjustment, complete the required information on the valve label (if supplied).
NOTE: If the diverter stem has an E-clip and an O-ring, these must be removed before the actuator and
guide can be installed.
Position the actuator over the diverter stem. Secure with setscrew.
1491056-2-A
4 of 14
1. WATER TEMPERATURE ADJUSTMENT
Tab
Valve Stem
Collar
2. DIVERTER ASSEMBLY (IF APPLICABLE)
Valve Stem
Diverter Stem
Diverter Actuator
Setscrew
Pressure Balance Trim
Standard Valve
Tab
Setscrew
Collar
Valve Stem
Discard plaster guard with dome.
Questions? Problems? For additional assistance, please contact KALLISTA's Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or kallista.com.
Valve Label
O-Ring