Floating Magnets - Balluff BTL PF Serie Manual De Instrucciones

Ocultar thumbs Ver también para BTL PF Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 85
BTL PF _ 400- _ _ _ _ -C12NL _ _ -0-000S04
Magnetostrictive Linear Position Sensor – Profile Style
5
Installation and connection (continued)
5.3

Floating magnets

Observe the following when installing the magnet:
To ensure the accuracy of the magnetostrictive linear
position sensor, fasten the magnet to the moving
member of the machine only using non-magnetizable
screws (stainless steel, brass, aluminum).
The moving member must guide the magnet on a
parallel line to the BTL.
Distance A between the magnet and parts made of
magnetizable material must be kept to at least 10 mm
(see Fig. 5-4 to Fig. 5-8).
For distance B between the magnet and the BTL and
for the center offset C (see Fig. 5-4 to Fig. 5-8) the
following values must be maintained:
Magnet type
BTL5-P-3800-2
BTL5-P-5500-2
BTL5-P-4500-1
BTL6-A-3800-2
BTL6-A-3801-2
The selected distance must remain constant over the entire measuring
1)
length.
For optimal measurement results: 6...8 mm
2)
Tab. 5-1:
Distance and offset for magnets (see Fig. 5-4 to Fig. 5-8)
A
A
Fig. 5-4:
Dimensions and spacing with magnet BTL5-P-3800-2
A
A
Fig. 5-5:
Dimensions and spacing with magnet BTL5-P-5500-2
www.balluff.com
Distance B
Offset C
1)
0.1...4 mm
±2 mm
5...15 mm
±15 mm
0.1...2 mm
±2 mm
4...8 mm
±5 mm
2)
4...8 mm
±5 mm
2)
C
C
Plug with
A
A
LED
4
Fig. 5-6:
Dimensions and spacing with magnet BTL5-P-4500-1
A
A
Fig. 5-7:
Dimensions and spacing with magnet BTL6-A-3800-2
A
A
Fig. 5-8:
Dimensions and spacing with magnet BTL6-A-3801-2
C
C
C
english
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Btl pf1400-0500-c12nl3a0-000s04

Tabla de contenido