Troubleshooting; Specification - Furrion FCR16DCASA-BG Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting

Before contacting the Furrion Customer Service:
1. Try to solve the problem yourself following the points described in the table below.
2. Turn off the appliance and restart it to see if the fault persists.
Trouble
Appliance is not switched on
RV batteries are empty.
No display on the
display panel
Fuse is blown or defective
DC connecting wires are intermittent / broken
Alarm sound
Door is slightly open or not closed fore more than 1 minute
Under defrosting mode
Compressor doesn't
DC12V power source voltage is too low or DC12V
work
power source is too weak.
Floor is uneven or week
Vibrating noise
Items placed on the top of the fridge are vibrating
Fridge touches the wall or cabinet
Layer of Frost in
Blocked air outlets
compartment
Doors can't be
Blockage
closed easily
Damaged LED
Light is not working
Control system disabled lights

Specification

Specifications
Total Capacity
15.6 cu. ft. (442L)
Freezer Capacity
6.08 cu. ft. (172L)
Fridge Capacity
9.54 cu. ft. (270L)
Noise (dB)
≤42dB
Door Type
Side by Side
Handle
Recessed Handle
Control Type
LED Display with electronic control
No. of Shelves
6
No. of Crisper
4
Cooling Type
Compression cooling system
Possible Cause
Switch on the appliance.
Recharge the DC12V power source (by connecting RV to the shore
power).
Check fuse, replace if necessary.
Such malfunctions are to be corrected by an electrician.
Close the door completely.
Normal for defrosting.
Charge / replace DC12V power source.
Be sure the floor is even and solid and can adequately support the fridge.
Remove items.
Move fridge so that it does not touch the wall or cabinet.
Check air outlets not blocked, ensure food placed in appliance has
sufficient ventilation
• Check nothing internal is trapped in the door.
• Tilt the refrigerator back to allow self-closing mechanism
Contact Manufacturer
If door has been left open too long lights will be deactivated. Close &
reopen the door to activate
Refrigerant
R600a
Rated Voltage
DC 12V
Rated Current
19A (≤ 20A)
Power Consumption
667kWh/year
Off-Grid Rating
5.3Ah @ 77°F (25°C)
Refrigerator: 32°F to 43°F (0°C to 6°C) adjustable
Temperature Range
Freezer: -10°F to 5°F (-23°C to -15°C) adjustable
Working Temperature
50°F to 110°F (10°C to 43°C)
Range
Defrost
Automatic
Certification
CSA
- 14 -
Solution
Specifications
CCD-0005509 Rev: 03-08-22

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fcr16dcasa-ss20211238152021123827