Prevent solvents, oils, greases, acidic or caustic substances and detergents to come into contact
with the external plastic and brass parts of the equipment. In case of very strong bumps during
transport or assembly, do not install the equipment and replace it even if there are no patent
damages to the plastic parts.
B1.3 General instructions for installation
Once the packaging has been removed, check the pump integrity. If doubt, do not use it
-
and contact the supplier. Make sure that all listed parts are present.
Check that the pressure and temperature of the supply water are within the technical data
-
of the equipment. In case of network pressures higher than the maximum pressure even for
short period, install a protective pressure reducer upstream. The pressure must be at least
1,5 bar.
The Manufacturer declines all liability for damages to property or persons resulting from the
-
incorrect installation of the pump and/or the installation of the pump in a system not
complying with the laws in force.
The plumbing system in which the pump is installed and the installation of the pump itself must be
carried out in compliance with best practice, in line with all the current laws in force.
All materials used for the construction of water plumbing systems must be suitable for contact with
water intended for human consumption according to local laws.The construction and modification
of a water distribution system intended for human consumption requires performing the
interventions in such a way as not to jeopardize the hygiene of the system. Before installing the
pump, clean all piping and equipment installed before the pump in order to remove any foreign
bodies that could cause pump malfunction. After the installation the plumbing system intended for
human consumption must be washed and/or disinfected according to the requirements of the EN
806-4 standard. It is advisable to install a protection filter upstream of BravaDOS in order to avoid
blockages due to coarse materials.
B1.4 Hydraulic checks after installation
After opening the water upstream of the equipment check for leaks;
1.
Check for the correct installation of the pump in order to facilitate ordinary maintenance
operations.
2.
Verify the presence of a by-pass circuit that permits the exclusion of the pump and the
presence of sampling faucets upstream and downstream of the pump.
3.
Check the correspondence of the system to any local regulations or recommendations
issued by the competent local area offices.
4.
Check periodically that AcquaSIL 2/15
the refill bag has to decrease proportionally with water treated). If this is not the case, please
contact Acqua Brevetti SRL (telephone: +39.(0)49.8973432 e-mail
MAN 116 – Rev.7
BravaDOS - ENGLISH
is regularly consumed (the amount of product inside
®
servizi@acquabrevetti.it
PAG.E-12
).

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bravados pm012Bravados pm014Bravados pm016

Tabla de contenido