• When the device is used together with
other devices powered with non-electrical
energy, the negative pressure of the room
must not exceed 4 Pa (4 x 10
• This manual must be stored for future con-
sultation at any time. If sold, transferred or
moved, it must remain with the device.
Electrical Requirements
• Disconnect the device from the electrical
network
• The installation must be performed by
professionally qualified personnel familiar
with the applicable installation and safety
standards.
• The manufacturer declines any liability to
people, animals or things in the case of
failure to follow the guidelines provided in
this chapter.
• Make sure that the voltage on the rating
plate on the bottom of the device corres-
ponds to that of the house where it will be
installed.
• Do not use extension cords.
• Earthing is required by law

IMPORTANT

Observe all governing codes and ordinances.
It is the customer's responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is
adequate and in conformance with National
Electrical Code, ANSI/NFPA 70 — latest
edition*, or CSA Standards C22.1-94,
Canadian Electrical Code, Part 1 and C22.2
No.0-M91 - latest edition** and all local
codes and ordinances.
If codes permit and a separate ground wire
is used, it is recommended that a qualified
electrician determine that the ground path is
adequate.
Do not ground to a gas pipe.
Check with a qualified electrician if you are
not sure range hood is properly grounded.
Do not have a fuse in the neutral or ground
circuit.
IMPORTANT
Save Installation Instructions for electrical
inspector's use.
-5
bar).
The appliance should be connected directly
to the fused disconnect (Or circuit breaker)
box through metal electrical conduit.
Wire sizes must conform to the
requirements of the National Electrical Code
ANSI/NFPA 70 — latest edition*, or CSA
Standards C22.1-94, Canadian Electrical Code
Part 1 and C22.2 No. 0-M91 - latest edition**
and all local codes and ordinances.
A U.L.- or C.S.A.-listed conduit connector
must be provided at each end of the power
supply conduit (at the appliance and at the
junction box).
Copies of the standards listed may be
obtained from:
* National Fire Protection Association
Batterymarch Park Quincy, Massachusetts
02269
** CSA International 8501 East Pleasant
Valley Road Cleveland, Ohio 44131-5575
Preparation of the device/cooktop for
installation:
the device should only be lifted and installed
by two or more people.
• The exhaust air should not be vented into
• After unpacking the product, check that it
• Check that the product is the right size for
• Check for accessories (e.g. bags contain-
WARNING
:
This is a heavy product;
a wall, a ceiling, or a concealed space of a
building.
has not been damaged during transport
and in the event of problem, please con-
tact the reseller or the Customer support
service before installing it.
the installation area.
ing screws, warranty certificates, etc.) in-
side the packaging (placed there for trans-
port reasons). Remove and keep them
safe, if present.