Install the Door Control
2 Wire the door control to the door operator
PRE-WIRED INSTALLATIONS: When wiring the door control to the door operator make sure you use the same wires
that are connected to the door control.
1.
Run the white and red/white wire from the door control to the door operator. Attach the wire to the wall and
ceiling with staples (not applicable for gang box or pre-wired installations). Do not pierce the wire with the
staple as this may cause a short or an open circuit.
2.
Strip 7/16 inch (11 mm) of insulation from the end of the wire near the door operator.
3.
Connect the wire to the red and white terminals on the door operator. To insert or release wires from the
terminal, push in the tab with screwdriver tip.
1
Staple
3
2
7/16" (11 mm)

3 Attach the warning labels

1.
Attach the entrapment warning label on the wall near the door control with tacks or staples.
2.
Attach the manual release/safety reverse test label in a visible location on the inside of the door.
18