Broan Elite EIT1366SS Manual De Instrucciones página 4

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALL CEILING SUPPORT
1. At hood location
CEILING
install
2
x
4
JOISTS
cross
framing
between ceiling
joists
using
d i m e n s i o n s
shown.
Make
sure
framing
does
not
CROSS
FRAMING
interfere
with
electrical outlet
CEILING
box opening in
MOUNTING
PLATE
ceiling mounting
plate.
2. Install
house
(8) M6 x 40mm
wiring
and
WOOD
SCREWS
ductwork.
3. Finish ceiling
surface. Be sure to mark the location of the ceiling joists &
cross framing. Bring house wiring through finished ceiling.
4. Remove cover from electrical outlet box on ceiling mounting
plate. Pull house wiring through hole on top of mounting plate
and into electrical outlet box. Secure house wiring cable to
mounting plate / electrical box with appropriate connector.
5. Install ceiling mounting plate with the side marked "front"
at the desired hood location. Secure using (8) M6 x 40 mm
wood screws. Make sure screws are driven into the center
of the framing for maximum strength.
6" ROUND DUCTWORK
HOUSE
F R
O N
WIRING
T
ELECTRICAL
OUTLET
BOX
INSTALL THE HOOD
(Ducted Installation only)
1. Assemble
(4)
angle brackets
to
the
lower
hood mounting
locations using
(8) M4 x 10mm
pan
head
machine screws
(2 for each angle
bracket).
(16) M4 x 10 mm
PAN HEAD
MACHINE
SCREWS &
2. D e t e r m i n e
(16) M4
SERRATED
dimension
"H"
FLANGE NUTS
based
upon
ceiling
height
and height of
hood installation
above cooktop:
7-FT. 8-IN. CEILING
Hood 26" above cooktop H = 30"
Hood 30" above cooktop H = 26"
8-FT. CEILING
Hood 26" above cooktop H = 34"
Hood 30" above cooktop H = 30"
Hood 34" above cooktop H = 26"
9-FT. CEILING
Hood 26" above cooktop H = 46"
Hood 30" above cooktop H = 42"
Hood 36" above cooktop H = 36"
10-FT. CEILING (with Flue extension FXNEIT1SS)
Hood 26" above cooktop H = 58"
Hood 30" above cooktop H = 54"
Hood 36" above cooktop H = 48"
3. Attach the upper set of (4) angle brackets to the outside of
the lower angle brackets according to dimension "H". Use
(16) M4 x 10 mm pan head machine screws and (16) M4
serrated flange nuts (4 at each angle bracket connection).
4. Attach the angle bracket assemblies to the upper hood
mounting locations using (8) M4 x 10 mm pan head
machine screws (2 for each angle bracket).
MODEL EIT1366SS
Page 4
(8) M4 x 10 mm
PAN HEAD
MACHINE
SCREWS
1
7
/
"
1 6
(8) M4 x 10 mm
PAN HEAD
MACHINE
SCREWS
H

Publicidad

Tabla de contenido
loading

Tabla de contenido