INSTALL THE HOOD
(Non-Ducted Installation Only) (cont'd)
7. Measure
the
(4) M4 x 8 mm
length
of
6"
SHEET METAL
round
flexible
SCREWS
duct
required
from the blower
exhaust opening
NON-DUCT
to the ductwork
PLENUM
rough-in in the
ceiling. Connect
FLEXIBLE
the duct to the
DUCT
blower exhaust
opening, secure
with
tie
wrap
and seal with
duct tape.
BLOWER
EXHAUST
8. Attach
the
OPENING
a l u m i n u m
flexible duct to
the
non-duct
plenum
collar.
Make sure non-
duct
plenum
"front" is facing
front of hood.
Secure with tie
wrap and seal
with duct tape.
9. Remove
the
p r o t e c t i v e
coating from the
(8) M4 x 10 mm
inner flue. Turn
PAN HEAD
MACHINE
the inner flue so
SCREWS
that the louvers
are at the top.
Carefully
slide
the inner flue
down into the
outer
flue.
Slide the flues
over the angle
brackets. Make
sure the side
marked
"front"
faces the control
side of the hood.
Feed the power cable up through the flues.
10. Pull the inner flue up and attach the non-duct plenum with
collar to the upper flue using (4) M4 x 8 mm sheet metal
screws.
11. Attach the hood assembly to the ceiling bracket using
(8) M4 x 10 mm machine screws (2 for each support leg).
INNER
FLUE
F R O N
T
POWER
CABLE
OUTER
FLUE
DUCT
TAPE
F R
O N
T
INSTALL THE HOOD
(Non-Ducted Installation Only) (cont'd)
12. Connect power cable to house wiring inside of electrical
outlet box. Connect the neutral conductor of product
(WHITE) to the neutral conductor (WHITE) of the house
power cable, connect the live conductor of product
(BLACK) to the live conductor (BLACK) of the house
power cable and connect the grounding conductor of
product (GREEN) to the grounding conductor (GREEN)
of the house power cable. Secure power cable to wiring
box with appropriate wire clamp and re-attach outlet box
cover.
13. Slide the inner
flue up to the
ceiling
and
secure with (4)
M4 x 8mm sheet
metal screws.
14. Remove
the
(4) M4 x 8 mm
SHEET
p r o t e c t i v e
METAL
coating from the
SCREWS
hood and the
outer flue.
15. Remove
the
NON-DUCT
grease filters by
FILTER
MOUNTING
pulling down the
TABS
metal latch tab
and tilting the
filters downward
to remove.
16. Install
the
METAL
n o n - d u c t
LATCH
r e c i r c u l a t i o n
filter as shown.
Turn mounting
tabs on hood to
secure filter.
17. Reinstall grease filters by aligning rear filter tabs with
slots in the hood. Pull down the metal latch tab, push filter
into position and release. Make sure filters are securely
engaged after installation.
MODEL EIT1366SS
Page 7
NON-DUCT
RECIRCULATION
FILTER
GREASE
FILTERS