ALARM MANAGEMENT

If an anomaly occurs in the operation, the following procedure is activated:
1)
acoustic alarm (beep);
2) one of the following system LEDs lights up:
3) if the anomaly concerns an error, the stove will switch off.
Press and hold the
"cancel" key to display the error code:
ALARM
E001
Defective control panel
E002
Remote control communication signal error
E004
Communication error
Ignition failure error
E101
E105
Pellet probe alarm
E108
Safety switch error
E109
Pressure or electrical safety error
E106
Temperature probe malfunction
E111
Fume probe malfunction
Low pellet level. (flashing icon)
A001
Low pellet level
Scheduled maintenance warning. (flashing
A002
icon)
A004
Low battery
Pressure sensor malfunction.
A007
(flashing icon)
----
Stove cleaning
----
Ignition failure error
After checking the message type, it is possible to reset the alarm by pressing the on/off key
seconds.
If the error code is "E108", manually re-set the thermostat on the back of the stove before resetting the
alarm (Fig. 6.1) (to be performed by the technical support centre).
004779080 - 26/08/2022
ITALIANO
ENGLISH
DESCRIPTION
FRANÇAIS
DEUTSCH
;
POSSIBLE CAUSES
Defective control panel
Defective control panel
Connection cable between board and control panel
interrupted or disconnected.
If it appears during the configuration change, ignore
this error
Insufficient pellets
Pellet quality
Faulty ignition system
Dirty burn pot
Pellet probe disconnected or faulty
Sensor(s) connected to I01 (ref. Wiring diagram)
Pellet hopper overheating problems
Open connected sensor
Sensor(s) connected to I02 (ref. Wiring diagram)
Dirty fume evacuation system
Worn sealing gaskets
Insufficient combustion air
Defective air probe
Overheating problems
Defective fume temperature probe
Pellets depleted
Pellets finished
Periodically, the stove requires maintenance by a
specialist technician
The back-up battery (mod. CR2032) on the electronic
board is low *
Pressure sensor or faults card.
Combustion chamber, burn pot or dirty fume
evacuation.
Detached or blocked pressure detection tubes.
Blocked combustion air intake.
No pellets: Ignition resistor faulty;
Worn gaskets; Incorrect burn pot position