Weekly program (timer) 24hours/7days
Min 300 sets of time periods
Electronic thermoregulator with weekly program (timer) 24/7 - electronic room
temperature control plus weekly timer means the product is equipped with
an electronic device, either integrated or external, which allows the product
automatically to vary its heat output over a certain time period. In relation
with a certain required level of indoor heating comfort. It allows the setting
of timing and temperature levels for a full week. During the 7-day period the
settings must allow a variation on a day-to-day basis;
Activation and deactivation of Weekly program - /Quick start B10/
There have three options /Quick start B10/:
-
CREATE PROGRAM
-
ERASE PROGRAM
-
VIEW PROGRAM
The temperature of 22 ˚C started at 12.30 to 15.00 on Sunday. The convector
will heat till reach the settings of the next given point.
If the TIME PERIOD is empty (no time set) – visualization should be
OFF
.
- One step back – with single pushing of ON/OFF button
- No limit of time periods – step is 0.5 hour (30 minutes).
- Adaptive start function is switched on by default.
Function AirSafe – only for models CN 06 xxx EА CLOUD AS W, CN 06 xxx EА
AS W and CN 06 140 EА CLOUD AS W GL
Function Air Safe
The Air safe function Is a result of working together of the module, composed
of UVA LEDs and the convector heater.
Advantages of the function:
1. Better air hygiene and a healthier environment, thanks to the bactericidal
effect of the function.
2. Safe operation, even in the presence of people and animals - the light
emitted by the module is UVA, which is 95% of the UV light passing through
the atmosphere. The reflected UV light in the volume of the housing in which
the heater is located has a very low intensity and energy and has no harmful
effects on humans, plants and animals.
3. Without generation of ozone, hydrogen peroxide, organic or inorganic
molecules or ions
4. High degree of reduction of bacteria and fungi
5. Extremely long service life - over 50,000 hours (over 12 years).
6. Quite working mode – natural air flow, through the convector heater
Principle of work of Air safe function
The Air Safe function can be switched on and off by the user through the
convector control menu. In order to work, it is necessary the convector to
be switched on and heated (the set temperature is higher than the ambient
temperature).
When the temperature of the heater rises, the natural air flow starts in the
room.
Colder air enters through the lower openings of the convector and passes by
the UVA LEDs.
Due to this movement, the molecules of gases, bacteria, micromycetes (fungi)
and other microorganisms contained in or carried by the air are irradiated by
the combined effect of UVA LED radiation and the infrared radiation of the
heater. The continuous passage of the air flow through the volume of the
convector provides enough energy to break the connections supporting the
structure of harmful microorganisms carried by the air.
As a result of natural convection, after a certain period of time, the air
contained in the room completely passes through the volume of the
convector, which leads to a reduction of the bacteria and micromycetes
English
contained in it.
Function Air Safe is a protection against harmful organisms such bacteria and
fungi. Provides better air hygiene and benefits to а healthier environment.
The function can be switched Off manually.
Activation and deactivation of Air Safe function - /Quick start B11/
Operation of Air Safe must continue for 2 minutes after stopping the heating
element, and then turn off.
Built in tip-over switch /Quick start B12/– if the convector tilts with more
than 45° or falls down, the power must switch Off and indicate on display
''tilt'' . After restoring the device to its normal position, operation of the last set
function must continue.
Function Wi-Fi – only for models CN 06 xxx EA CLOUD AS W, CN 06 xxx
EA CLOUD W and CN 06 140 EА CLOUD AS W GL
Function Wi-Fi
Activation and deactivation of Wi-Fi Function and Wi-Fi Local Function - /
Quick start B15/
Work mode of display:
When pressed - backlight intensity - 100%; after 5s – OFF
Sound option
.
Activation and deactivation of sound function - /Quick start B14/
Device info
Visualization on Display in "Device info" /Quick start B13/
-
ID
-
MAC address
-
Firmware version
Quick menu /Quick start C 1 -5/
Push the "Mode" button
Content function:
-
Comfort
-
Eco
-
Sleep
-
Delay start
-
Weekly schedule
Exit from the any mode – with single pushing of ON/OFF button
Errors mode:
If the display shows "t1" or "t2", this means that the self-diagnostic system has
found a problem with the temperature sensor. "t1" indicates a disconnected
cable at the sensor, while "t2" indicates short circuit at the sensor. In this case
the electric convector will be automatically switched off and it can be switched
on again only after the problem has been fixed. The problem has to be handled
by a qualified specialist.
DISCONNECTION FROM THE POWER SUPPLY:
If the electric convector is disconnected from the mains, this will not affect
the set temperature and the mode of operation which has been active prior
to its disconnection. If for example the convector has been in "Heating" mode,
after it has been disconnected and reconnected to the mains, it will continue
operating in the same mode with the same set temperature.
The principle of operation of the electric convector with energy-independent
memory is to store the settings for 120 minutes guaranteed, and up to 180
minutes not guaranteed.
If the time is more than 120 min the appliance going to Stand by mode.
to start quick already configured program.
Operation and Storage Manual of Panel Heater