5.8

Aborted Welding Process

The welding process has failed if a plain-text error is dis-
played on the screen and the audible signal buzzes inter-
mittently. An error has to be acknowledged by pressing the
STOP/RESET key.
5.8

Cooling Time

The cooling time as given in the fitting manufacturer's in-
structions has to be respected. If the bar code provided by
the fitting manufacturer contains cooling time data, it will
be displayed at the end of the welding process and will be
counted down to zero. This countdown can be acknowl-
edged and canceled at any time by the STOP/RESET key.
However, note that for that time the pipe fitting joint which
is still warm must not be subjected to an external force. No
cooling time is displayed if the fitting code does not contain
any such information.
5.10

Returning to the Start of Parameter Input

After welding is finished, disconnecting the welded fitting
from the unit or pressing the STOP/RESET key will reset the
unit back to the start of entering the welding parameters.
6

Additional Information in the Welding Report

Every welding report saved to system memory, which can be
downloaded as a PDF report file or in the DataWork format,
contains a number of welding and traceability data that the
operator can decide to enter or not to enter in the set-up
menu.
6.1

Entering Preformatted and User-defined Traceability Data

All traceability data enabled in the configuration menu
at "Data Recording" (see Sect. 10) have to be entered be-
fore the welding process. The welding unit prompts the
user to enter them either before or after entering the fit-
ting bar code (see Display 2). Depending on what data is
entered, either its repeated input is mandatory (e. g., the
welder ID code; see Sect. 5.2) or previously entered data can
be changed and confirmed or confirmed without changes
(e. g. the commission number and the additional data; see
Sect. 6.2, 6.3).
Certain traceability data can also be accessed quickly, via
a selection screen, by pressing the  cursor key (see Dis-
play 6), either for viewing or for entering or changing/con-
firming them.
12
EN
HÜRNER HCU 300 User's Manual
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
***
Recording
Welder Code
>Commission Number
Version September 2022
***
Display 6