Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 60

7 MAINTENANCE

WARNING!
-
Before carrying out any routine maintenance operation, stop the Generator.
-
All maintenance operations not covered by this manual must be carried out in authorized service centers.
Ordinary maintenance operations can be performed by operators.
WARNING!
-
The engine must be properly maintained to ensure its operation be safe, economy and trouble-free, as well as
eco-friendly.
In order to keep your gasoline engine in good working condition, it must be periodically serviced. The follow-
ing maintenance schedule and routine inspection procedures must be carefully followed:
Items
Engine oil
Air filter element
Spark Plug
Spark arrester
Idling ( if equipped)*
Fuel tank & fuel filter *
Fuel line
* These items should be maintained and repaired by our authorized dealer, unless the owner has appropriate tools and
is proficient with mechanical
WARNING!
Stop the engine before servicing. Put the engine on a leve) surface and remove the spark plug cap to prevent the
engine from starting.
Do not operate the engine in a poorly ventilated room or other enclosed area. Be sure to keep good ventilation in
working area. The exhaust from the engine may contain poisonous CO, inhalation can cause shock, uncon-
sciousness and even death.
WARNING!
-
If the petrol engine often runs at high temperatures or with heavy loads, change the oil every 25 hours.
-
If the engine frequently work under dusty or other severe circumstances, clean the air filter element every l O
hours; If necessary, change the air filter element every 25 hours.
-
Respect the maintenance periods indicated.
-
If the due date for engine maintenance has not been met, take action as soon as possible.
AUTHORISED SERVICE POINTS
These are the centres authorised by the Manufacturer to repair the products.
Page 36
Frequency
Each time
Check-Refili
Replace
Check
Clean
Replace
Check-adjust
Replace
Clean
Check-adjust
Clean
Check
maintenance.
First I month or first
20 hrs of operation
Every year or 250 hrs of operation
Every 2 years ( change if necessary)
Use and maintenance manual – Translation of
original Instruction Rev.: 00, Date 01/03/2022
Thereafter, every
Every year or eve-
3 months or every
ry 100 hrs of op-
50 hrs ofoperation
eration

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido