TIP: If the engine stalls or does not start, turn the engine switch to „ON" and the pull the recoil starter. If the oil warning
light flickers for a few seconds, the engine oil is insufficient. Addo il and restart.
4.4

Overload indicator light (red)

The overload indicator light
tro) unit overheats, or the AC output voltage rises. Then, the AC protector will trip, stopping power generation in order to
protect the generator and any connected electric devices. The AC pilot light (Green) will go off and the overload indicator
light (Red) will stay on, but the engine will not stop running.
When the overload indicator light comes on and power generation stops, proceed as follows:
1. Tum off any connected electric devices and stop the engine.
2. Reduce the total wattage of connected electric devices within the rated output.
3. Check for blockages in the cooling air inlet and around the contro) unit. lf any blockages are found, remove.
4. After checking, restart the engine.
TIP: The overload indicator light may come on fora few seconds at first when using electric devices that require a large
starting current, such as a compressor or a submergible pump. However, this is not a malfunction.
4.5

AC pilot light (green)

The AC pilot light
comes on when the engine starts and produces power.
4.6

DC protector

4.7

Generator switch

- On:
Start the Generator
- Off: Stop the Generator