1/2" Pipe
2" (5.1 cm) Min.
3-1/2" (8.9 cm) Max.
1/2" Pipe
1. Prepare for Installation
NOTE: For bath-only and shower-only installations, seal the unused
outlet with the plug provided.
When the trim will include a slip-fit bath spout, 1/2" tubing must
extend 1-1/2" (3.8 cm) minimum to 2-7/8" (7.3 cm) maximum
beyond the finished wall at the bath spout location.
When the bath spout is threaded, the nipple must extend 3-7/8"
(9.8 cm) beyond the finished wall at the bath spout location.
Determine the installation location of the valve and install
support framing as needed.
Kohler Co.
All manuals and user guides at all-guides.com
4-1/2"
(11.4 cm)
72" (182.9 cm) -
6-3/4"
78" (198.1 cm) To
(17.1 cm)
Floor (Typical)
4"
(10.2 cm)
1/2" Pipe
1/2" Hot
1/2"
1/2" Pipe
Cold
Top of Rim
4-7/8"
48" (121.9 cm) to
(12.4 cm)
Floor (Shower Only)
3
8" (20.3 cm)
(Bath/Shower)
4" (10.2 cm)
(Bath Only)
4" (10.2 cm)
113725-2-AB