TALKOVER_ACTIVE
<Input=I4:I5>
TALKOVER_MODE
<Input=I4:I5>
TALKOVER_PRIORITY
<Input=I4:I5>
TALKOVER_ZONES
<Input=I4:I5>
TALKOVER_THRESHOLD
<Input=I4:I5>
TALKOVER_DEPTH
<Input=I4:I5>
TALKOVER_ATTACK
<Input=I4:I5>
TALKOVER_HOLD
<Input=I4:I5>
TALKOVER_RELEASE
<Input=I4:I5>
CHIME_MELODY
<Input=I4:I5>
CHIME_VOL
<Input=I4:I5>
XSELECT
<Input=I1:I5>
XLEVEL
<Input=I1:I5>
ZONE_LABEL
<Zone=ZA:ZD>
ZONE_STEREO
<Zone=ZA:ZD>
Gets the current TALKOVER status (ON or OFF) for the specified
INPUT
Gets the TALKOVER function working mode (PAGER or DUCKER) for
the specified INPUT
Gets the current TALKOVER PRIORITY level (LOW or HIGH) for the
specified INPUT
Gets the current TALKOVER assignment to outputs (ZONES) for the
specified INPUT
Gets the current TALKOVER THRESHOLD LEVEL (dBx10) for the
specified INPUT
Gets the current TALKOVER DEPTH (attenuation, dBx10) for the
specified INPUT
Gets the current TALKOVER ATTACK TIME (milliseconds x10) for the
specified INPUT
Gets the current TALKOVER HOLD TIME (milliseconds x10) for the
specified INPUT
Gets the current TALKOVER RELEASE TIME (milliseconds x10) for the
specified INPUT
Gets the current CHIME MELODY selected for the TALKOVER function
in PAGER mode
Gets the current CHIME MELODY VOLUME (dBx10) adjusted for the
TALKOVER function in PAGER mode
<Zone=ZA:ZD>
Gets the current CROSSPOINT SELECT status (ON (input active) or
OFF (input muted)) for the specified INPUT at the specified output
zone
<Zone=ZA:ZD>
Gets the current CROSSPOINT LEVEL (mix level) for the specified
INPUT at the specified output zone
Gets the current LABEL (name) for the specified output zone
Gets the current STEREO link status (ON or OFF) the specified output
zone