IN_VOL
<Input=I1:I5>
IN_BASS
<Input=I1:I5>
IN_MID
<Input=I1:I5>
IN_TREBLE
<Input=I1:I5>
HPF_ACTIVE
<Input=I4:I5>
HPF_FREQUENCY
<Input=I4:I5>
FBS_ACTIVE
<Input=I4:I5>
GATE_ACTIVE
<Input=I4:I5>
GATE_THRESHOLD
<Input=I4:I5>
GATE_DEPTH
<Input=I4:I5>
GATE_ATTACK
<Input=I4:I5>
GATE_HOLD
<Input=I4:I5>
GATE_RELEASE
<Input=I4:I5>
TALKOVER_ACTIVE
<Input=I4:I5>
TALKOVER_MODE
<Input=I4:I5>
TALKOVER_PRIORITY
<Input=I4:I5>
TALKOVER_ZONES
<Input=I4:I5>
<Volume=0:99>
<Gain=dBx10>
<Gain=dBx10>
<Gain=dBx10>
ON/OFF
<Frequency=Hz>
ON/OFF
ON/OFF
<Threshold=dBx10>
<Depth=dBx10>
<AttackTime=msx10>
<HoldTime=msx10>
<ReleaseTime=msx10
>
ON/OFF
PAGER/DUCKER
LOW/HIGH
<Zones=ZA:ZD>
43
Sets the current VOLUME for the specified INPUT (general input
volume, affecting all the post processing)
Sets the current BASS tone LEVEL for the specified INPUT
Sets the current MIDDLE tone LEVEL for the specified INPUT
Sets the current TREBLE tone LEVEL for the specified INPUT
Sets the current HIGH PASS FILTER status (ON or OFF) for the specified
INPUT
Sets the current HIGH PASS FILTER frequency (Hz) for the specified
INPUT
Sets the current FEEDBACK SUPPRESSOR feature status (ON or OFF)
for the specified INPUT
Sets the current NOISE GATE status (ON or OFF) for the specified
INPUT
Sets the current NOISE GATE THRESHOLD LEVEL (dBx10) for the
specified INPUT
Sets the current NOISE GATE DEPTH (attenuation when gate is closed,
dBx10) for the specified INPUT
Sets the current NOISE GATE ATTACK TIME (milliseconds x10) for the
specified INPUT
Sets the current NOISE GATE HOLD TIME (milliseconds x10) for the
specified INPUT
Sets the current NOISE GATE RELEASE TIME (milliseconds x10) for the
specified INPUT
Sets the current TALKOVER status (ON or OFF) for the specified INPUT
Sets the TALKOVER function working mode (PAGER or DUCKER) for
the specified INPUT
Sets the current TALKOVER PRIORITY level (LOW or HIGH) for the
specified INPUT
Sets the current TALKOVER assignment to outputs (ZONES) for the
specified INPUT. Zones parameter can include ZA to ZD, separated by
comma characters and no blank space (example: ZA,ZC,ZD)