Troubleshooting
Problem
Insufficient water
Supply pressure inadequate
Cartridge filters dirty
Showerhead or handshower filter dirty
Crossflow: hot water forced into
Check valves dirty or worn
cold water supply or vice versa
when mixture is closed
Output temperature does not
Handle not justified
correspond with temperature
marked on handle
Water heater set too low
Safety stop button not operating
Button and/or spring are dirty or worn
Handle hard to turn
Cartridge dirty or worn
Shower or spout dripping
Volume control cartridge dirty or worn
Temperature regulation not possible (new installation) Hot and cold supplies
are reversed
Thermostatic cartridge dirty or worn
Maintenance
• Inspect the check valves at least once per year.
Replace the check valves if necessary.
• Should the volume of water decrease over time,
inspect and clean the filters on the thermostatic
cartridge. After reassembly, set the high
temperature limit stop and justify the handle.
• To prolong the life of the themostatic cartridge,
regularly run it through its full range of
temperatures.
Possible Cause
Solution
Check water pressure
Clean the filters (see page 28)
Clean the filter
Clean check valves, replace if
necessary
Justify the handle
Increase the hot water temperature
Clean spring and button, replace if
necessary
Replace cartridge
Clean or replace volume control
cartridge
Turn the function block 180°
Replace the thermostatic cartridge