Cleco CellCore CCBA Manual De Instrucciones página 14

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1
1
EN
EN
Problem
Work light disabled.
Control menu on tool is not en-
abled or only partially enabled.
No-load speed not reached.
Expected number of run-
downs is not achieved with one
charge of the battery.
Software does not boot.
WLAN data communication problems between controller and tool
Problem
No WLAN data communication
between the controller and
tool.
IP address cannot be pinged.
Occasional interruptions in
WLAN data communication.
14
Possible cause
Disabled by parameter setting.
Disabled by parameter setting.
Battery voltage is too low.
Battery is not fully charged.
The warning threshold for un-
dervoltage is not set to the
minimum value.
High torque is needed during a
fastening sequence, e.g., for
coated fasteners.
Battery has too many charging
cycles.
Error in the main software.
Possible cause
The IP address of the tool is
not correctly entered in the
controller.
Tool is already assigned to an-
other controller.
IP address already exists in
the network. In this case, the
tool will not establish a connec-
tion.
Distance between the access
point and the tool is too great.
Excessive data traffic on
WLAN network.
P2390BA | 2022-10
Measure
Parameterize the tool light on the controller
screen: Navigator> Advanced > Tool Group > Ex-
tended Tool Settings.
To activate the work light:
To enable the control menu:
Use a fully charged battery.
Use fully charged battery.
Reduce the Undervoltage (V) on the control
screen: Navigator > Tool Setup > Tool Settings >
Others > Low Level [V].
To set the warning threshold:
If a high torque is needed for a longer period of time,
e.g., for several turns, the number of run-downs that
can be achieved with one battery charge will be signif-
icantly reduced.
After 800 charging cycles, the capacity is reduced to
approx. 60%.
Press the following keys:
Use recovery SD card. Contact Sales & Service
Center, see back page.
Measure
1.
Check on the control screen: Navigator > Tool
Setup, whether the IP address of the tool has
been entered in the box Type.
2.
Otherwise, mark the line and <Edit>.
IP address of tool
see Tool in submenu WLAN com-
munication.
Check the WLAN settings and make sure that the
WLAN settings for the controllers are different.
Applies only to WLAN infrastructure customers:
Check whether another controller already has a
connection to this tool. In other words, another
controller is using the same IP address.
Check the physical connection (RSSI values):
>
Check the assigned IP address.
1.
Check signal strength at tool in the submenu Sig-
nal Strength:
>
2.
If necessary, reduce the distance between the
access point and the tool.
Reduce data traffic on WLAN network.
1.
On the Basic control screen, increase the Trigger:
Navigator > Basic Application Builder > Trigger
Torque.
2.
Disable the torque graph data transmission on
Navigator > Advanced > Controller > General >
Trace Recording. For this, select the entry Rec-
ord in the column Off.
>
>
>
Apex Tool Group

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cellcore ccbp

Tabla de contenido