Items Supplied; Transport / Storage; Product Description - Cleco CellCore CCBA Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

a)
Our insulation is not insulation in the sense of VDE
standards: Hold the device at the insulated handle
surfaces when you perform work where the screw can
strike hidden power lines or your own power cable.
Contact between the screw and a live power line
could energize metal parts of the tool and cause an
electric shock.
b)
Hold the tool firmly. Be prepared for torque reaction.
c)
Reaction bars are recommended in applications with
limited space and when using:
Inline tools used above 4 Nm.
-
Pistol tools used above 10 Nm.
-
Angle tools used above 60 Nm.
-
d)
NEVER rest your hand on the reaction bar when
working.
e)
Check that the suspension bail is properly secured to
the balancer.
Personal Protective Equipment
When working with rotating parts, it is not permitted to
wear gloves.
Recommendation: Freely rotating u-GUARD pro-
tected fastening tools from APEX.
Wear a hair net, if necessary.
Power Tool Use and Care
Only use bits or sockets designed for industrial use
with machine-controlled tools.
Make sure that the bit or socket is securely inserted.
Do not attach the bit or socket to the screw head at an
angle.
Inspect the bit or socket for visible damage and
cracks. Replace damaged screw bits immediately.
Do not open the battery.
3

Items Supplied

Correct tool (without battery)
Instruction manual
EU Declaration of conformity
Warranty
4

Transport / Storage

Transport or store in the original packaging. The
packaging is recyclable.
If the packaging is damaged, check the product for
visible damage. Inform the transporter, if necessary,
your Sales & Service Center.
Disconnect the power supply during storage. Refer to
see chapter 8.4 Ambient conditions, page 12.
5

Product Description

Battery powered hand held nutrunner used for the tighten-
ing / loosening of threaded fasteners:
Apex Tool Group
Work Light for secondary OK/NOK visual feedback.
change. Stay alive time = 20 sec.
On-tool Digital Transducer and Servo provide critical
information and eliminate errors.
Connects easily over WLAN and Bluetooth 4.0.
Fig. 1-1: Product Description CCBA(...)/CCBP(...)
1
Micro USB-B Port
2
Display
3
Function Keys
4
Battery Pack
5
Start Trigger
6
LED Work Light
7
Output Drive
8
Micro USB Cable (Option: 962194PT)
Display
Default settings:
White
Tool running
Work Light
Default settings:
Blue
Tool running
P2390BA | 2022-10
Green
Red
OK rundown
NOK rundown
Green
Red
OK rundown
NOK rundown
1
1
EN
EN
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cellcore ccbp

Tabla de contenido