Only use included switches. Only use wires suitable for at least 90oC (194oF).
HIGH
Motor speed
selection
switch
(3-way)
LOW
HC0108
NOTES: 1.
If the HCK44 Power cord kit is used to connect the unit, install the provided ground screw (A)
on the unit grounding plate.
2. Use appropriate wire nuts for all connections.
Punch-out the other knock-out opening. Insert both 14/2 cable coming from
switches in the hood through an UL approved wire clamp. Connect BLACK wire
from house wiring cable to BLACK wire from no. 2 14/2 cable.
With a short ground wire (not provided), connect all ground wires together as
shown at right. Connect the other end of the short ground wire to the GREEN
ground screw.
Cap off the hood BLACK wire using an appropriate wire nut.
Connect WHITE wire from house wiring cable to both WHITE wires from hood.
Connect WHITE wire from no. 2 14/2 cable to BLUE wire (light).
Connect BLACK wire from no. 1 14/2 cable to ORANGE wire (high speed).
Connect WHITE wire from no. 1 14/2 cable to RED wire (low speed).
Once all the connections are done, reinstall the wiring compartment cover in the unit;
ensuring the bottom tabs are inserted in their embossed location. Secure in place
using its retaining screw
NOTE: Be careful while reinstalling the wiring cover to the hood.
Take care not to pinch wires while reinstalling wiring cover.
ON/OFF
Motor switch
ON/OFF
Light switch
OFF - ON
CAUTION
CAUTION
COM
Motor
speed selection
switch
HE0436A
Install 2 included rocker switches at a convenient place for the user.
Use two 14/2 cable to wire the switch box to the range hood (see
diagram above).
HO0412
2
WHITE
BLACK
WHITE
GROUND
NO. 1
NO. 2
14/2 CABLE
14/2 CABLE
TO HOOD
TO HOOD
HD1371
5
6
4
7
HOUSE
WIRING
CABLE
NO. 1
14/2 CABLE
HE0439A
On/Off
motor switch
On/Off
light switch
A
2
1
NO. 2
14/2 CABLE
TABS