L (mm)
W (mm)
590
Under any circumstances, make sure the Induction cooker hob is well ventilated and the air inlet
and outlet are not blocked. Ensure the Induction cooker hob is in good work state. As shown be-
low:
The safety distance between the hotplate and the cupboard above the hotplate should be at
least 760mm.
A (mm)
760
Before you install the hob, make sure that:
•
The work surface is square and level, and no structural members interfere with space require-
ments.
•
The work surface is made of a heat-resistant material.
•
If the hob is installed above an oven, the oven has a built-in cooling fan.
•
The installation will comply with all clearance requirements and applicable standards and regu-
lations.
•
A suitable isolating switch providing full disconnection from the mains power supply is incorpo-
rated in the permanent wiring, mounted and positioned to comply with the local wiring rules and
regulations.
•
The isolating switch must be of an approved type and provide a 3 mm air gap contact separation
in all poles (or in all active [phase] conductors if the local wiring rules allow for this variation of
H (mm)
520
55
B (mm)
C (mm)
50 mini
20 mini
D (mm)
A (mm)
51
560
D
Air intake
B (mm)
X (mm)
490
50 mini
E
Air exit 5mm
39