4.8 Chiller operation
4.8.1
Status machine
It is possible to see the status machine on the digital output
Stato
Descrizione
chiller OFF
Unit Status
:
chiller ON
Unit Status
:
4.8.2
Pump
The pump starts together with the chiller, a few seconds later.
It turns off together with the chiller, a few seconds later.
4.8.3
Compressor
The ON/OFF of the compressors depends on the water outlet
temperature (b1) with reference to the "set" and "dif" param-
eters.
The compressor ON/OFF logic depends on the ambient tem-
perature.
Ambient Temperature
ON/OFF compressor
> 10°C
step control
< 10°C
together
Example
set = 7°C; dif = 4 ° C; ambient temp. <10°C
- when the water inlet temperature reaches 9 ° C (7 + 2) :
compressor 1 starts;
- when the water inlet temperature reaches 11 ° C (7 + 4):
compressor 2 starts.
set = 7°C; dif = 4 ° C; ambient temp. >10°C
- when the water inlet temperature reaches 11 ° C (7 + 4) :
compressors 1 and 2 starts;
Warning: a compressor can only restart after a stop of 6
minutes.

4.9 Alarms management

(P1)
When the button
is red, una alarma está presente.
Press the button to see the type of alarm.
es:
HP1
High pressure Alarm
Circuit 1
English
Note: eliminate the cause of the fault for clear the alarm.
Carry out the repair.
(P1)
press the button
If this message appear "noAL"
noAL
HP1
High pressure Alarm
Circuit 1
(P1)
press the button
to reset the alarm.
4.9.1
Digital input alarms
CODE
DESCRIPTION
HP1
High pressure alarm 1 from pressure switch
LP1
Low pressure alarm 1 from pressure switch
Pump thermal cutout alarm
tP
Water tank low water level alarm / No water
LL
fl ow
HP2
High pressure alarm 2 from pressure switch
LP2
Low pressure alarm 2 from pressure switch
Protection alarm compressor 1
PI1
/ Phases monitor
Protection alarm compressor 2
PI2
/ Phases monitor
Hyperchiller 076-116
4.9.2
Analog input alarm
AI
CODE
DESCRIPTION
Tank water outlet water high tem-
HA1
perature alarm
Tank water outlet water low tem-
b1
LA1
perature alarm
St1
Sensor open circuit or short circuit
Evaporator water outlet water high
HA2
temperature alarm
b2
Evporator water outlet water low
LA2
temperature alarm
St2
Sensor open circuit or short circuit
High ambient temperature
HA3
(antifreeze) warning
b3
Low ambient temperature
LA3
(antifreeze) warning
RESET
Sensor open circuit or short circuit
St3
M
Water tank high ambient tempera-
M
HA5
ture alarm
M
Water tank low ambient tempera-
b5
LA5
ture alarm
A
St5
Sensor open circuit or short circuit
M

4.10 Automatic restart

M
In the event of a power failure, when power is restored the
chiller will assume theOn-Off statusheld at themoment the
M
power was lost.
M
RESET
Warning
A
M
Warning
A
M
Warning
Warning
M
Warning
Warning
M
7/10

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hyperchill ice090Hyperchill ice116

Tabla de contenido