COMPONENTS (Picture 1)
1
control panel
2
light indication
3
rollers
4
handle
CONTROL PANEL (Picture 2)
POWER:
Press the button to turn the unit on or off
MODE:
Please press the button to select between auto dehumidification and manual
dehumidification.
TIMER:
You can determine the switch-on or switch-off time by entering the desired number
of hours (0-24) with the key. If you select "00", the timer is deactivated.
LOCK:
Child lock. Please press and hold the button to unlock/lock all buttons.
SPEED:
Please press this key to select the desired fan speed.
HUM:
Press these buttons to change the humidity level settings.
OPERATION INSTRUCTIONS
Attention: These functions are only available when the room temperature is between 5°C-35°C and the
humidity is between 20%-90%.
Switching the device on/off
-
Please plug in the power plug of the dehumidifier.
-
Please press the POWER button to turn on the device.
-
The unit will start with high fan speed and humidity level setting of 50%.
-
Please press the POWER button again to deactivate the unit. The fan will continue to run for 30
seconds.
Timer
Power off time:
-
Please press the TIMER button while the unit is running to set the off time.
-
The time can be set by the hour (0-24h) with the TIMER button.
Switch-on time:
-
Please press the TIMER key while the device is switched off to determine the switch-on time.
-
The time can be set by the hour (0-24h) with the TIMER button.
Deactivate timer:
-
Please press the up / down button repeatedly until '00' is shown on the display.
Continuous dehumidification - Auto dehumidification – Sleep Mode
-
Please press the "MODE" button to select between continuous and auto dehumidification mode
or sleep mode.
-
In continuous dehumidification mode, the unit is always set to high ventilation speed and 20%
humidity. This cannot be changed in this mode.
-
In automatic dehumidification mode, the unit starts automatically with a dehumidification level of
50%. You can set the desired dehumidification level by operating the "HUM" button.
-
If the relative humidity in the room is higher than the set dehumidification level (+3%), the unit
runs at a higher fan speed.
-
If the relative humidity in the room is lower than the set dehumidification level (-3%), the
dehumidification function switches off and the fan runs for 30 seconds.
5
air inlet & dust filter
6
water tank
7
drainage opening
8
air outlet