Installation
A
Fig. . . . . 17
Fig. . . . . 17
Fig
Fig
Fig
Fig
17
17
17
17
Fig
Fig
Fig
Fig
17
17
17
17
Fig. . . . . 18
Fig
Fig
18
18
Fig
Fig
18
18
14
D
A
B
C
5. 5. 5. 5. 5. Position the ceiling frame on
the ceiling as shown in Fig. 15
and mark the holes on the wall.
Also drill the securing holes (8
mm (
5
/
") diameter drill bit)
16
and then fit dowels in them.
6 . 6 . 6 . 6 . 6 . In the top securing holes of
the drilling template, fix 2
hooks A A A A A with screws (5 x 45
mm) (Fig. 17).
7. 7. 7. 7. 7. The wall extractor can then be
hooked in. Adjust the unit with
the screws B B B B B and D D D D D (Fig. 17).
8. 8. 8. 8. 8. The two bottom screws C C C C C (5 x 45
mm) can be screwed into the
bottom securing holes in the
housing interior, each with a
shim (Fig. 17). This protects the
extractor against levering out.
9. 9. 9. 9. 9. Make wiring (Fig. 18):
W W W W W ARNING:
ARNING:
ARNING:
ARNING:
ARNING: Turn OFF power
circuit at the service panel
before wiring this unit.
- a circuit of 120V AC, 15 or 20
AMP is required.
- Remove the cover of the
Junction box (situated close to
the body of the motor
housing) and install a 1/2"
conduit connector on it.
- run 3 wires black, white and
green (#16AWG) in 1/2"
conduit from service panel to
junction box.
- Connect black wire from
service panel to black or red
in junction box, white to white
and green to green-yellow.
- Close junction box cover.