OPERATING AND MAINTENANCE MANUAL
PMO SERIES 4" SUBMERSIBLE MOTOR
4. ISOLATION PROCESS
1.
The bottom part is tensioned with three layers by the insulating rubber strip and should be fixed.
2.
The outer layer is tensioned at 30~50% half load with four layers by PVC waterproof strip, each layer
is gradually extended outward, and should be fixed.
5. WIRING DIAGRAM
MOTOR
THREE-PHASE:
MOTOR
SINGLE-PHASE:
BROWN
6. MAINTENANCE
1.
Regularly check the insulation resistance between the winding and the motor housing. The insula-
tion resistance must exceed 1MΩ when approaching operating temperature. Otherwise, other co-
rresponding measures should be taken.
2.
After normal operation for 2500 hours, maintenance work must be carried out according to the
following measures:
•
Oil change: Unscrew the oil plug to fill the oil chamber with 10# mechanical oil to 80-90%
of its capacity.
•
Pressure test: The pressure test shall be carried out after repair or replacement. The pressu-
re must remain 0.2 MPa with 3 minutes until there is no leakage or sweating.
www.proindecsa.com / proindecsa@proindecsa.com
BLACK
BLUE
BROWN
BLACK
BLUE
YELLOW-GREEN
8