This chapter lists the most common problems linked with the use of the appliance. If you are unable to resolve the problems with the
information given here, please contact your nearest assistance centre.
PROBLEM
POSSIBLE CAUSE
The main switch is in the rest position.
The power cable extension is not connected to
the mains socket.
The appliance's electronic specifications do not
match the mains supply specifications.
The power cable is damaged.
The vacuum hose is not properly connected to
the vacuum nozzle.
The vacuum hose is not properly connected to
the accessory in contact with the floor.
The collection tank cover has not been properly
positioned.
The collection bag has not been positioned
correctly.
The collection bag is full or was torn.
The fabric filter is not correctly positioned.
The fabric filter is clogged or has torn.
The vacuum hose is blocked.
The vacuum chamber of the accessory in
contact with the floor is blocked.
Dust coming out during vacuuming.
The cap of the vacuum nozzle has not been
closed properly.

CONTROL AND OPERATION

Place the main switch on "I".
Connect the power cable plug to the mains socket.
Check that the technical information on the serial number plate
correspond to the mains supply information.
If the power cable is damaged replace it, immediately contact an
authorised TMB technical assistance centre.
Connect the vacuum hose to the nozzle on the collection tank.
Connect the vacuum hose to the accessory that is being used to
do the vacuuming.
Place the cover on top of the collection tank and secure it using
the side hooks.
Remove the collection tank cover and position the collection bag
correctly.
Remove the cover of the collection tank and empty the collection
bag or else change it (see the paragraph "CHECKING AND
CLEANING THE COLLECTION BAG").
Remove the collection tank cover, remove the collection bag and
position the fabric filter correctly.
Remove the collection tank cover, remove the collection bag
and clean or replace the fabric filter (read the paragraph
"CONTROLLING AND CLEANING THE FABRIC FILTER").
Check that there is nothing obstructing the vacuum hose, if there
is, remove it.
Check that there is nothing obstructing the vacuum chamber of the
accessory being used, if there is, remove it.
Read the paragraph "DUST COMING OUT DURING VACUUMING".
Insert the cap into the vacuum nozzle correctly.