BASIC MENU

+
(diagram C)
- Press simultaneously
- By mean of
or
- Press
for validation.
- This is the parameters sequence:
TYPE
SYSTEM REACTION
bar psi We can select the pressure units
displayed beetween bar and psi.

ADVANCED MENU

- Press simultaneously
- By mean of
or
- Press
for validation.
- The parameters sequence is:
SCREEN
SYSTEM REACTION
Activation of the automatic restore
Ar0
Ar1
system ART (Ar1) o disable (Ar0).
In case of enabled ART, it can be
n01
n48
set the number of restore at-
tempts, between 1 and 48.
It can be set the span of the at-
t10
t40
tempt between 10 and 40 seconds.
Stand-by disabled (Sb0) or
Sb0
Sb1
enabled (Sb1)
Anti-flooding configuration.
If activated, it stops the pump
after programmed time (in hours)
H00
H99
of continuous operation.
Disabled (H00), 1 hour (H01) ... 24
hours (H24).
rs0
rs1
Restore factory settings (rs1)
+
during 5 seconds.
the values can be changed.
+
+
+
+
during 5 seconds.
the values can be changed.

PRESSURE SENSOR CALIBRATION

In case of wrong lecture of the pressure sensor it can be
adjusted again.
For the pressure sensor calibration is necessary to have a
pressure gauge in the installation. Proceed following next
steps:
ZERO REGULATION
FACTORY
1.
Open the taps living the hydraulic net without pressure.
SETTING
2.
Press simultaneously the buttons
display show 0.0 flashing.
bar
3.
Press
FULL SCALE
1.
Set the outlet pressure equal to the maximum pressure
of the pump. In case of using a pump with higher pres-
sure than 6 bar, set the outlet pressure to 6 bar. (Go to
the point 4 of the STARTUP to remember how to set the
outlet pressure)
FAC-
2.
Start the device and wait until it stops the pump.
TORY
3.
Press simultaneously the buttons
SET-
play flashes with a figure.
TING
4. Adjust the pressure with the arrows push-buttons to get
the pressure desired.
Ar1
5.
Press
Examples:
48
MAXIMUM PUMP
15"
PRESSURE
4 bar
0
8 bar
Remark: pressure sensor decalibration should not be
H00
a normal event. If it is frequently repeated contact the
technical service.
rs0
7
to validate.
to validate.
OUTLET
PRESSURE
4 bar
6 bar
and
until the
and
till the dis-
ADJUSTED FULL
SCALE
4 bar
6 bar