4.2.3 Special key programming
If the preset function do not reflect requirements, EACH KEY can be programmed differently by carrying out the steps below.
Special key programming allow to programm the following functions:
• generic actuator and coded actuator (ACT)
• internal intercom calls and general intercom calls to another user code (INT)
• internal paging calls and general paging to another user code (PAG)
• Self activation main external unit (AI)
• Automatic lock-relase (Doctor mode) (D)
4.2.3.1 HOW TO PROGRAM THE ACTUATOR FUNCTION
Example:
key
√
Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
Set S2 DIP switch 5-6 to the combination 01
» the Privacy LED flashes
2
1. Choose the function: refer to the
combination in which the actuator function (ACT) is listed for the keys you wish to program.
2. Addressing:
for generc actuator set S1 DIP switches to the combination 11111111
for coded actuator set S1 DIP switches with the desired address in accordance with
"TABLE A" on page 25
3
Select the key to be associated with the function
Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
4
Exit programming mode
To exit programming mode, set S2 DIP switches 5-6 to the combination 00
» the Privacy LED switches off
5
When programming is complete,
Set S2 DIP switches 1-2-3-4 to the combination 1111 (PROG setting). In this DIP switch
setting, the keys control the programmed functions; the NON-programmed keys control
functions referred to on line 0000, see
Restore the user code setting on S1.
4.2.3.2 HOW TO PROGRAM THE INTERCOM FUNCTION
Example:
key = general intercom to user code 3
√
Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
Set S2 DIP switch 5-6 to the combination 01
» the Privacy LED flashes
2
1. Choose the function: refer to the
combination in which the intercom function (INT) is listed for the keys you wish to program.
2. Addressing:
for internal intercom set S1 DIP switches with the same user code of the internal unit.
for general intercom to another user code set S1 DIP switches with the desired address
in accordance with
3
Select the key to be associated with the function
Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
4
Exit programming mode
To exit programming mode, set S2 DIP switches 5-6 to the combination 00
» the Privacy LED switches off
"Preset function table"
"Preset function
"Preset function table"
"TABLE A" on page 25
and select a S2 DIP switches
table".
and select a S2 DIP switches
ON
1 2 3 4
5
6 7
8
Example: 1010
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
Example: 0100
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
21