Quick Programming; Special Key Programming; How To Program The Actuator Function - Comelit HFX-9500M Manual Tecnico

Ocultar thumbs Ver también para HFX-9500M:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4.2.2 Quick programming

For the quick programming of the following functions:
• generic actuator (ACT),
• internal intercom calls (INT),
• internal paging calls (PAG),
• Self activation main external unit (AI),
• Automatic lock-release (Doctor mode) (D)
1
„ Set the S2 DIP switches
combination corresponding
to the functions that you want
to programme for ALL KEYS
as shown in the table
function".

4.2.3 Special key programming

If the preset function (see page 21) do not reflect requirements, EACH KEY can be programmed differently by carrying out the steps
below.
Special key programming allow to programm the following functions:
• generic actuator and coded actuator (ACT),
• internal intercom calls and general intercom calls to another user code (INT),
• internal paging calls and general paging to another user code (PAG),
• Self activation main external unit (AI),
• Automatic lock-release (Doctor mode) (D)

4.2.3.1 HOW TO PROGRAM THE ACTUATOR FUNCTION

Example:
key
Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
„ Set S2 DIP switch 5-6 to the combination 01
» the Privacy LED flashes
2
2.1 Choose the function: refer to the
switches combination in which the actuator function (ACT) is listed for the keys you wish to
program.
2.2 Addressing:
„ for generc actuator set S1 DIP switches to the combination 11111111
„ for coded actuator set S1 DIP switches with the desired address, see page
A" .
3
Select the key to be associated with the function
„ Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
4
Exit programming mode
„ To exit programming mode, set S2 DIP switches 5-6 to the combination 00
» the Privacy LED switches off
5
When programming is complete,
„ Set S2 DIP switches 1-2-3-4 to the combination 1111 (PROG setting). In this DIP switch
setting, the keys control the programmed functions; the NON-programmed keys control
functions referred to on line 0000. Page
„ Restore the user code setting on S1.
22
Example:
Choose S2 DIP switches combination
DIP 1
DIP 2
0
1
"Preset
for set all the following function
INT
21 "4.2.1 Preset function"
21 "4.2.1 Preset function"
DIP 3
DIP 4
0
0
INT
ACT
NULL
table and select a S2 DIP
27 "TAB.
table.
AI
PAG
ON
1 2 3 4
5
6 7
8
Example: 0100
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8

Publicidad

Tabla de contenido
loading