when welding in the Weld Control mode, will be
wrong! Changing to another machine requires consul-
tation with the manufacturer or a service shop, as a sen-
sor calibration is then also recommended. Performing
this step requires properly briefed technicians.
As an addition to the preinstalled machines, user-defined
machine types can be set as needed at the unused menu en-
tries (a designation for the machine and the cylinder section
of its clamping chassis have to be entered).
The Sensor Parameters sub-menu, used to calibrate the pres-
sure and the temperature sensors, should be accessed by au-
thorized staff only and is, therefore, protected by another
access code disclosed only to such personnel as is allowed to
manage these settings.
4.1.1
Configuring the Fundamental Operating Settings of the Machine
In the sub-menus of the configuration menu, at "Settings,"
the parameters related to the welding system itself and its
operation can be set. At "Recording," the traceability data
that have to or need not be recorded and written into the
reports can be enabled or disabled. The desired sub-menu is
selected using the ñ and ò cursor keys. Then, to access that
sub-menu, press the MENU key.
In both parts of the configuration menu, use the ñ and ò
keys to select the desired set-up option. Use the ð cursor
key to toggle between "on" and "off" for that option.
If a "M" is shown next to a set-up option, this indicates that
a sub-menu is accessible here by pressing the MENU key.
On both menu levels (Configuration Menu and its
respective sub-menus), press the START/SET key to
save the settings to memory or press the STOP/RE-
Important
SET key to return to the previous menu level with-
out saving possible changes.
4.1.2
Understanding the "Settings" Sub-menu
"Check Code Expiry on" means that the welder identifica-
tion code has to be current and not expired (default pe-
riod of validity 2 years from code issuance), or the weld-
ing operation cannot be started, "off," that the validity
of the code is not checked at all.
"Memory Control on" means that when the system memory
is full of reports, the system will be blocked until the
reports are printed or downloaded, "off," that it works
but that the oldest report will be overwritten.
"Automode on" means that in the Weld Control mode the
Automode feature for the easy management of the
Version November 2022_1
Weld Control 315 User's Manual
SETTINGS
***
***
Check Code Exp. Off
Memory Control
On
>Automode
On
Display 6