Descargar Imprimir esta página

Cameo P2 T Manual De Usuario página 28

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 83
Minimum distance to
normally flammable
materials
Dimensions
(L x W x H)
Weight
RDM UID
MINIMUM DISTANCE TO ILLUMINATED SURFACE
This symbol with distance specification in metres (m) indicates the minimum
0.5 m
distance between the light head and the illuminated surface. In this example, the
distance is 0.5 m. The value applicable for this unit can be found in the technical
data in this manual and the imprint on the unit housing!
MINIMUM DISTANCE TO NORMALLY FLAMMABLE MATERIALS
This symbol with distance specification in metres (m) indicates the minimum
0.5 m
distance between the light head and normally flammable materials. In this example,
the distance is 0.5 m. The value applicable for this unit can be found in the
technical data in this manual!
28
0.2 m
633.3 mm x 330.7 mm x 314 mm 633.3 mm x 330.7 mm x 314 mm
Engine and lens holder
(as shipped): 8.9 kg
Light engine: 7.3 kg
Lens holder: 1.6 kg
19° lens: 1.5 kg
26° lens: 1.46 kg
36° lens: 1.35 kg
50° lens: 1.35 kg
15° – 30° lens: 5.8 kg
25° – 50° lens: 4.5 kg
0x08A4011B (0000-FFFF)
0.2 m
Engine and lens holder
(as shipped): 8.9 kg
Light engine: 7.3 kg
Lens holder: 1.6 kg
19° lens: 1.5 kg
26° lens: 1.46 kg
36° lens: 1.35 kg
50° lens: 1.35 kg
15° – 30° lens: 5.8 kg
25° – 50° lens: 4.5 kg
0x08A4011A (0000-FFFF)

Publicidad

loading

Este manual también es adecuado para:

P2 dClp2tClp2d