Setting / programming the UP and DOWN travel times
Automatic mode and automatic mode with random function
Each keystroke must be made within 4 seconds. Otherwise, the system automatically exits the programming mode!
Before you start programming, first select the channel to be programmed with the K2 and K1 keys.
Programming in group mode (all channels are selected at the same time) is NOT possible.
The programmed time between UP and DOWN must be at least 35 minutes.
Otherwise the value will not be accepted (Er-01 appears in the display)!
1.
Switch to automatic or automatic with random function mode. (see p. 11)
2.
Press and hold the K2 key. After approx. 5 seconds, the symbol for UP and Mo (Monday) appears.
Release the key.
3.
Then briefly press the K2 key again. The hour display flashes.
4.
Use UP and DOWN keys to set the desired hour of automatic UP time for Monday.
5.
Then briefly press the K2 key again. The minute display flashes.
6.
Use UP and DOWN keys to set the desired minute of the automatic UP time for Monday.
7.
Then briefly press the K2 key.
8.
The display changes to the setting of the automatic DOWN time for Monday.
9.
The hour display for setting the automatic DOWN time for Monday flashes
10. Use UP and DOWN keys to set the desired hour of automatic DOWN time for Monday.
11. Then briefly press the K2 key again. The minute display flashes.
12. Use UP and DOWN keys to set the desired minute of the automatic DOWN time for Monday.
13. Then briefly press the K1 key.
14. The display changes to the setting of the automatic UP and DOWN times for Tuesday.
15. The symbol for UP and Tu (Tuesday) appear in the display.
16. The hour display flashes.
Now proceed as for setting the UP and DOWN times for Monday.
To confirm the set values, press the K1 key again for approx. 5 seconds.
The hour and minute displays flash simultaneously.
The programming of the up and down times is completed, the settings are saved.
To program further channels (1-5), please start from the beginning.
To execute the set automatic UP and DOWN times (switching times), the respective channel (individual control) or the
group control must be activated (highlighted in black). Respective channel (individual control) or the group control must
be activated (highlighted in black)! (see page 19 - Individual and group control)
Channels that are not activated are not controlled!
PROGRAMMING
25