Section 3. In-line Installation
DO NOT INSTALL chlorine feeder before the heating system. Damage to
the heating system may occur.
In order to prevent risk of serious property damage, injury or death:
Wear eye and skin protection while maintaining or servicing this unit.
Do not inhale fumes from the chlorinator or chemical container.
Chlorine feeder may be under pressure. Use caution removing cover.
12-5/8in
[319mm]
Figure 3.
Feeder Dimensions
1. Install unit downstream of the filter and heater (if present).
IMPORTANT: Heaters and other equipment may be damaged by highly chlorinated
water. A check valve should be installed before the erosion feeder to avoid damage to
heater.