Page 8
5. The outlet connection must be made downstream of the heating system or, if no
heating system is installed, downstream of the filter. This connection will be feeding
treated water from the dosing unit into the plumbing system.
FROM
POOL
FROM
POOL
Figure 5.
Off-line Installation Configuration
6. Flex pipe installation Use four compression nuts, four compression insert cones, and
black flex tube, included with unit.
a. Cut the dosing tube to the required lengths, ensuring the cuts are clean, square and
free of burrs.
b. Attach the inlet and outlet line to the feeder by installing the compression nut and
cone over tubing. Push tubing onto the tapered end of the inlet. Tighten the nut
firmly by hand (Figure 6).
c. Drill 3/4" hole in plumbing and remove any burrs.
d. Insert one plumbing nipple into the plumbing clamp for the inlet line. Install the
clamp assembly for the inlet (line going TO feeder) and outlet (line FROM feeder)
by installing the clamp assembly (Figure 7).
NOTE: Be sure the outlet connection is after the heater, filter, etc.
e. Install the remaining compression nuts and cones over the free ends of the tubing
then push tubing onto tapered ends of the pipe nipples. Tighten the nuts firmly by
hand.
7. Hard pipe installation Use four ½" socket nuts and four o-rings (included), and ½"
Sch 40 pipe (not included).
ENGLISH
PUMP
INLET
INSTALLATION WITH HEATER
PUMP
INLET
INSTALLATION WITHOUT HEATER
Jandy
TruChlor Erosion Feeder
®
FEEDER
RETURN
TO POOL
CHECK
VALVE
OUTLET
FEEDER
RETURN
TO POOL
OUTLET
|
Installation & Operation Manual