ABIPLAS
CUT HF
NOTICE
• Over-tightening can damage the thread.
3 Attach the swirl ring.
NOTICE
• Ensure that it is positioned correctly.
• The air holes should always point towards the electrode tip.
4 Attach the selected plasma nozzle.
• The type of plasma nozzle used is primarily determined by the thickness of the material to
be cut and the current intensity.
Tab. 3 Product-specific torch data (EN 60974-7) on page EN-6
• The following standard values apply:
Type
ABIPLAS
ABIPLAS
Tab. 8
BAL.0716.0 • 2022-01-11
®
CUT 71 HF/71 HF MT
®
CUT 111 HF/111 HF MT
Standard values
Plasma
ø
nozzle
[mm]
Standard
0.9
Standard
1.1
Standard
1.2
Long
0.9
Long
1.1
Cross slot
0.9
Cross slot
1.1
Long cross slot
0.9
Standard
1.0
Standard
1.2
Standard
1.4
Standard
1.6
Long
1.2
Long cross slot
1.2
Gouging
2.6
7 Operation
Current intensity
[A]
30
30–60
50–70
30
30–50
30
30–60
30
30–50
40–70
70–90
90–110
50
50
EN - 15