INSTALLATION & OPERATION
PUMP INSTALLATION
INSTALL A SHALLOW WELL PUMP
The 1/2 HP FP4512 and 1 HP FP4532 pumps are recommended
for wells 25 feet or less in depth . If desired, the FP4542 and
FP4562 pumps may be converted for use with shallow wells
using an ejector kit (See REPAIR PARTS KIT) .
GENERAL MATERIALS REQUIRED
One can PVC cement (read instructions carefully)
One can thread compound (read instructions carefully)
One 1-1/4" foot valve
Two male 1-1/4" PVC adapters
Enough rigid 1-1/4" PVC pipe and couplings to reach
operating depth
One well seal with vent plug
One 1-1/4" PVC elbow
One discharge tee
One pressure gauge
One male 1" PVC adapter
Enough rigid 1" PVC pipe to reach from pump to pressure
tank to service line
REMINDER: ALL JOINTS AND CONNECTIONS MUST BE AIRTIGHT . A SINGLE PINHOLE LEAK WILL
PREVENT THE PROPER OPERATION OF THE PUMP . USE THREAD COMPOUND ON ALL THREADED
1.
Thread 1-1/4" male PVC adapter into
foot valve. Hand tighten, then
tighten 1/4 turn with wrench.
2.
The total length of rigid PVC pipe
and couplings to cement onto the
1-1/4" male PVC adapter is equal to
the operating depth (See Determine
Operating Depth). Cement one
section of rigid PVC pipe to the PVC
adapter which is connected to the
foot valve, then lower the whole
assembly into the well, foot valve
first. Firmly clamp the end of the
rigid PVC pipe with a pipe clamp to
prevent the assembly from sliding
further into the well.
6
IN ADDITION TO GENERAL MATERIALS, FOR THE FP4542
AND FP4562 CONVERTIBLE ONLY
One ejector kit (See REPAIR PARTS/KITS); includes ejector,
venturi tube, gasket, bolts and plug.
TOOLS NEEDED FOR ALL PUMP INSTALLATIONS
Pipe wrench, pipe clamp, crescent wrench, slot screwdriver,
24-tooth hacksaw, knife or round file.
CONNECTIONS UNLESS SPECIFIED OTHERWISE .
1-1/4"
MALE PVC
ADAPTER
FOOT
VALVE
3.
PVC
7125 1016
PIPE
SECTION
1-1/4"
MALE PVC
ADAPTER
FOOT
VALVE
7126 1016
One female 1" PVC adapter
One 1" tank cross (for pre-charged tanks)
Two 1/4" plugs
One 1/2" drain cock
One 10" x 1" nipple
Cement as many couplings and
sections of rigid PVC pipe as it
takes to equal the operating depth,
then firmly clamp the assembly
with a pipe clamp to prevent the
assembly from sliding down into
the well.
7082 0716
FP1002 (02-01-2023)

Publicidad

loading

Este manual también es adecuado para:

Flotec fp4532Flotec fp4542Flotec fp4562