Descargar Imprimir esta página

Kongskilde MultiCutter MCC GR80 Manual Operativo página 5

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Adjustment of the fixed knife:
The knives are adjusted by the manufacturer. So this instruction shall only be used after repairs.
1)
Check that the screws (pos. 3) are tightened.
2)
The screws (pos. 2) are turned till "hand tight".
3)
The screws (pos. 4) are tightened sufficiently so that the fixed knife (pos. 1) is just touching
the rotor blades. During tightening the rotor is turned manually and it must be checked that
the resistance against turning is equal for all rotor knives.
4)
The screws (pos. 5) are tightened and the position of the knives is checked by feeding a thin
piece of paper down between the knives, while the rotor is turned manually. It must be
checked that each rotor knife is cutting over its total length. The screws
(Pos. 2) are tightened and the check is repeated. If the knives are not cutting evenly
adjustment is made by means of screws (pos. 4 and 5).
5)
The blower is turned off at the electric control unit and the Granulator is turned on.
If the Granulator is making noise the screws (pos. 4) are loosened and the screws (pos. 5) are
tightened until the noise stops. To avoid damaging the knives adjustment, while running,
must be done with extreme care and therefore the screws (pos. 2) must not be loosened.
Manual_GR80_060123_EN
EN
3

Publicidad

loading