Descargar Imprimir esta página

SunPower Maxeon E-Series Instrucciones De Seguridad E Instalación página 7

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 66
The  bifacial  modules  can  be  mounted  both  landscape  or  portrait 
orientation as shown in Appendix section. 
When installing a bifacial module on a roof, check applicable building 
codes and ensure that the roof construction and the structural load 
calculations of the building are suitable. 
Bifacial gain tends to be most effective with a higher tilt angle.  
As the tilt angle and the module elevation from the underlying surface 
increases, more reflected light and diffuse light can be captured by the 
module.  The  mounting  rails  shall  be  designed  to  limit  the  rear  side 
shading  as  much  as  possible.  Obstacles  between  modules  and  the 
ground should be avoided as much as possible in order to increase the 
bifacial gain. 
 
5.5 Bifacial Electrical Considerations 
The overall electrical bifacial gain is determined by the combination of 
surface albedo, irradiance, module tilt angle, shading losses from the 
rearside,  rearside  mismatch  and  module  elevation  above  ground. 
Please refer to the Maxeon datasheet for the electrical outputs with 
respect  to  the  overall  bifacial  gain.  Please  utilise  a  suitable 
performance software package to simulate the overall bifacial gain. 
 
5.6 Handling of Modules during Installation 
Do  not  place  modules  face  forward  in  direct  contact  with  abrasive 
surfaces like roofs, driveways, wooden pallets, railings, stucco walls, 
etc... 
The  module  front  surface  glass  is  sensitive  to  oils  and  abrasive 
surfaces, which may lead to scratches and irregular soiling. 
During storage, modules need to be protected from rain or any kinds 
of liquids. Required storage temperature is between 10°C to 40°C in a 
dry environment (humidity between 30 to 80%). Do not store modules 
outdoor to avoid moisture and wet conditions. 
 
Modules that feature antireflective coated glass are prone to visible 
finger  print  marks  if  touched  on  the  front  glass  surface.  Maxeon 
recommends handing modules with anti‐reflective glass with gloves 
(no leather gloves) or limiting touching of the front surface.  Any finger 
print  marks  resulting  from  installation  will  naturally  disappear  over 
time or can be reduced by following the washing guidelines in Section 
6.0  below.  Any  module  coverage  (colored  plastic  tarps  or  similar) 
during installation can lead to permanent front glass discoloration and 
is  not  recommended.  The  use  of  vacuum  lifting  pads  can  cause 
permanent marks on the front glass. Never lift or move the module 
using the cables or the junction box under any‐circumstances. 
Shading  incidence  need  to  be  avoided  during  PV  system  operation. 
The  system  is  not  supposed  to  be  energized  until  the  mounting 
scaffolding, fences or railing have been removed from the roof. 
Systems should be disconnected in any cases of maintenance which 
can  cause  shading  (e.g.  chimney  sweeping,  any  roof  maintenance, 
antenna/dish installations, etc). 
6.0 Maintenance  
Maxeon  recommends  visual  inspection  on  a  regular  basis  of  all 
modules  for  safe  electrical  connections,  sound  mechanical 
connection, and free from corrosion. This visual inspection should be 
performed  by  trained  personnel.  The  standard  frequency  is  once  a 
year  according  to  environmental  conditions,  periodic  cleaning  of 
modules is recommended but is not required.  Periodic cleaning has 
resulted  in  improved  performance  levels,  especially  in  regions  with 
low levels of annual precipitation (less than 46,3cm (18,25  inches)). 
Consult  your  dealer  or  supplier  about  recommended  cleaning 
schedules for your area. 
 
To clean a module, wash with  potable, non‐heated, water.  Normal 
water pressure is more than adequate, but pressurized water up to 
100  bar  (min.50  cm  distance)  may  be  used.  Maxeon  recommends 
using  a  large  hosepipe  and  not  to  perform  cleaning  at  high  outside 
© June 2022 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this manual are subject to change without notice. 
Safety and Installation Instructions ‐ Document 001‐15497 Rev.X
temperatures.  Fingerprints,  stains,  or  accumulations  of  dirt  on  the 
front surface may be removed as follows: first rinse off area and let 
soak for a short period of time (5 mins). Re‐wet and use a soft sponge 
or seamless cloth to wipe glass surface in a circular motion.  
 
Fingerprints typically can be removed with a soft cloth or sponge and 
water  after  wetting.  Do  not  use  harsh  cleaning  materials  such  as 
scouring  powder,  steel  wool,  scrapers,  blades,  or  other  sharp 
instruments  to  clean  the  glass  surface  of  the  module.  Use  of  such 
materials or cleaning without consultation will invalidate the product 
warranty. As dry cleaning is also risky for Anti‐Reflective (AR) coated 
module  surface,  spinning  brush  is  not  recommended  for  module 
cleaning. 
 
 
 
 
 
 
 
 