SANARIUM C
7.
Troubleshooting
7.2.
Further possible faults
Error
The control unit will
not switch on.
Display:
Fault message 91.
Display:
Fault message 92
(SANARIUM C).
Buzzing sound at the
heater.
Steam does not exit
(SANARIUM )
(SANARIUM C).
The cabin light is not
illuminated after
switching on.
The fan will not run.
Output A1 dead.
Output A1 dead
5070188/07.02
Cause
No mains voltage.
The touch-sensitive safety
switch (SKS) above the
heater has triggered.
Maintenance required:
Decalcify evaporator.
Lack of water.
Cable failure.
Heating rod defective.
Lamp defective.
No mains voltage.
Fuse SI100 has triggered.
Fan defective.
Remedial action
Check the FI switch and fuse in the power
supply.
Check in the cabin whether there is anything
on top of the heater. If so, remove the
object.
Check whether the grille is loose. If so,
reinsert the grille.
Decalcify evaporator.
'
See Chapter 8.1.
Fill evaporator C with water.
'
See Chapter 5.8.
'
Inform the servicing personnel at Klafs.
Change lamp.
1.
Disconnect the control unit from the
mains.
2.
Insert lamp with the same power rating.
Check the FI switch and the fuse in the
power supply.
Replace fuse SI100 (1.25 AT) or inform the
Klafs Service.
Change fan.
1.
Disconnect the control unit from the
mains.
2.
Insert fan with the same power rating.
Continued on the next page
PAGE 21