8.
Care and maintenance
8.1.
Evaporator - SANARIUM C
Note!
Allow work on electric components /groups to be carried out only by electricians who
work in accordance with the electrotechnical regulations.
Emptying SANARIUM C
1.
Put the filling can (4) under the outlet (5). Open
the drain cock (1).
2.
After the evaporator is emptied, close the drain
cock (1) again.
3.
Empty the filling can (4).
Decalcifying SANARIUM C
4.
Take off the scent bowl (2) on the evaporator.
5.
Fill the evaporator with water at the evaporator
container (3).
6.
Put approx. two tablespoons of conventional
household decalcifier (chlorine-free!) into the
evaporator container (3).
7.
Allow the decalcifying solution to take effect no
the layer of lime overnight, or for at least
12 hours. This reaction time can always be made
2-3 times longer to be absolutely sure that all lime
deposits are detached.
8.
Put the filling can (4) under the outlet. Open the
drain cock (1). Drain the water into the filling
can (4).
Rinsing SANARIUM C
9.
Close the drain cock (1).
10. Take off the scent bowl (2) on the evaporator.
11. Fill the evaporator with water at the filling unit (3).
12. Put the filling can (4) under the outlet (5). Open
the drain cock (1).
13. After the evaporator is emptied, close the drain
cock (1) again.
14. Repeat the rinsing procedure two to three times.
Reset Fault 92 on the control unit
15. Delete the fault message with the OK button
during stand-by mode.
PAGE 24
5
4
2
SANARIUM C
1
3
1
5070188/07.02