13 Assembling the Blower
If the LED flashes red: there is no electric contact
between the battery and the charger. Remove
and reinsert the battery.
or
The battery has a malfunction and must be
replaced. Check the LEDs on the battery. Do not
use or charge a battery if its LEDs indicate a
malfunction.
or
The charger has a malfunction. Have it checked
by an authorized STIHL servicing dealer before
use.
For more information, @ 23.
13 Assembling the Blower
13.1 Mounting and Adjusting the Nozzle
WARNING
Make sure the battery is removed before starting assembly.
Never operate your blower without a properly mounted
blower tube and nozzle, @ 5.6.4. Use only attachments
supplied or expressly approved by STIHL, @ 5.5.
The nozzle can be mounted to the blower tube in three
positions to suit the height and reach of the user. The
positions are marked on the blower tube.
0458-008-8601-A
To mount the nozzle:
3
► Push the locking lever (1) and hold it in this position.
► Adjust the nozzle (3) by sliding it into the desired position
on the blower tube (2).
► Release the locking lever (1).
The nozzle should lock in position.
14 Inserting and Removing the Battery
14.1 Inserting the Battery
WARNING
Never use a malfunctioning, damaged, cracked, leaking or
deformed battery, @ 6.1. Use and store the battery only
within an ambient temperature range of 14 °F to 122 °F (- 10
°C to 50 °C), @ 6.1.
WARNING
To reduce the risk of unintended activation, never store the
battery in the blower, @ 20.2.
English
1
2
19